Profile:Completed substion/box substation
ZBW-12/0.4 HV/LV Pre-assembled Substation, also called box transformer substation,
is suitable for 3-phase AC power transformation and distribution system of rated input voltage 12kV,
rated output voltage 0.4kV, rated frequency 50Hz and rated capacity 1600kVA and below.
It is used for ring net work or terminal power supply of residence communities, malls and hotels,
industrial and mining enterprises, municipal works, big construction site and temporary construction sites, etc.
Note:All of products can be customized and designed by our engineers for you.
Advantages of our company:
1. long-term manufacturer of wold top 500 enterpriese
2. has more than 12 engineers --can service for you in time
3. skilled staff with min 5 years working experiences
4. located among the capital of electric and electrical products ,can get materials and compoinents in time
5. design and customized products for customers
6. enough experiencs in tenders/projects. work as bidders in the worldwide sometimes
7.accomplished many projects in the worldwide
8. subsidiary factory in South african is under -establishing
9.huge distributor net in the african market,and many distributors in the worldwide.
Complete Substation/Box substation consist of :
high voltage switchgear, low voltage switchgear, transformers...
All of them can design and make for you.
Features of completed substation/box substation
Common power ratings:
30, 50, 80,100,125,160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500 kVA.
This transformer is designed for voltages of ≤ 36 kV.
Specific figures are not given for this parameter because of the wide variety of voltages used.
Transformers can be supplied on demand to run at two different primary voltages, the shift between these input voltages has two
basic alternatives:
• with a primary tap changer which can be switched with no load and no applied voltage
• or by changing terminals under the cover.
The secondary voltage under no load is allocated at 400V, 415V, 433V, though other voltages can be supplied on demand.
When usage requires two voltages, transformers with two simultaneous voltages can be supplied.
In this case the no-load voltages are set to 400V(230V),415V(240V),433V(230V) .
As per IEC /BSEN 60076 standards these are
set in accordance with the highest voltage for the material,
being the level immediately above the rated voltage.
Material maximum admissible voltage | 12KV | 17.5KV | 24KV | 36KV |
Withstand voltage | 28KV | 38KV | 50KV | 70KV |
Basic insulation level | 75KV | 95KV | 125KV | 170KV |
Construction details--examples:
I-Outside
Four lifting hooks
II-Medium voltage compartment
Bolted-on terminal compartment with removable front sill
Hinged, lift-off cabinet doors
Interlocked hex-head or penta-head bolt padlock handle operates a cam assembly that is part of the three point door latching echanism
Hex-head or penta-head bolts must be removed from the flange formed on the steel high/low barrier before the HV door can be opened-not shown
Removable neutral ground strap
Tank ground pads
Steel high/low voltage compartment barrier
Nameplate
Fill plug and self-actuating
pressure relief device
Externally operated no load
Tap changer
Drain valve and sampling device
III-Low voltage compartment
Main circuit breaker
Current transformer(CT)
Meter
Outgoing feeder