Medium Voltage Surge Arrester

HY5WS-12.7/50L, HY5WS-16.5/50L, HY5WS-17/50L, HY5WS-17.5/50L, these appliances used to protect electrical equipment from high transient over-voltage hazards and to limit the duration of the current and often limit the range of the current.
  • Product Description
  • Overview:

    HY5WS-12.7/50L zinc oxide surge arresters with metal-oxide surge arresters in addition to the over-voltage protection function

    but also in the event of abnormal failure freauency short-circuit current from the device that moves the around automaticall

    disengage, withdraw from the grid of zinc oxide surge arresters operationrepair and maintenance convenienteasy to find fault


    →Arrester with disconnector works Description:

    When zinc oxide arrester failure,mainly increasing the current flowing through the valveso vaive group showed a fever state

    due to valve group and negative temperature coefficientthe equivalent resistance caused by heat down.and to promote heat


    intensifies.the formation of a vicious cycleThis arrester workina state to pass directly throuah the form of temperature from the

    device,when the temperature reaches the value from design to low melting point alloy melting,from the device moves out of the

    arrester and ground wire.cut out the defective arrester operationand aive a clear sianal patrol officers for the realization of oxide

    lightning"state maintenance"provides practical technical measures


    Installation and precautions:

    Arrester insulated by a bracket or clamp fixed to the cross armthe upper bolt connected hiah-volfane wire the lower nart of the 

    ground must be soft copper wire and grounding wire connections;not allow the use of hard-wire connection with the arrester ground

    to avoid lightning damage from the device can not be successfully divorced from


    The main technical parameter of surge arrester:

    Arrester model

    Rated

     voltage

     system

    Arrester

     rated 

    voltage

    Continuous

     operating

     voltage

    DC

     reference 

    voltage

    (U1mA)

    1/10ustee

    p wave impulse

     residual voltage current

    8/20us Residual

     voltage under 

    lighting surge 

    current

    30/60us The 

    impact of 

     current residual

     voltage

     operation

    2ms

     Square-

    wave flow 

    capacity 

    (2ms)

    4/10us High 

    current 

    impulse

     withstand


    KV(r.m.s)

    >/kV
    AkA
    HY5WS-38/15*33.82.07.517.31512.87540
    HY5WS-5/15
    54.08.017.31512.810065
    HY5WS-7.6/30*67.64.015.0
    34.53025.57540
    HY5WS-10/30
    108.015.034.53025.510065
    HY5WS-12.7/50*1012.76.625.057.550.038.57540
    HYW5WS-17/50
    1713.625.057.550.038.510065