+86 139 6879 9444 / +86 151 5777 5432
  • Outdoor Voltage transformer
  • Outdoor Voltage transformer

Outdoor Voltage transformer

EJDZZW -33R outdoor voltage transformer
EJDZXW-33R outdoor voltage transformer
  • Product Description
  • Type description:

    E--Company name:Enboli

    J--Voltage transformer

    D--Single-phase

    Z--Casting insulation

    W--Outdoor type

    33-Rated voltage(kV)

    R--With melt tube

     


    Technical data

    Type

    Rated

     voltage

     ration(V)

    Accuracy class and 

    rated secondary output(VA)

    Max.

    output(VA)

    Rated 

    insulation 

    level(kV)

    Wiring 

    diagram

    0.2

    0.5

    1grade

    3 grade

    0.2/0.2

    0.5/0.5

    6p

    0.20.5

    EJDZW-33

    33000/100/100

    30

    50

    300

    600

    /

    /

    /

    1200

    36/70/170

    Fiagure 1-2

    33000/100/220

    /

    /

    /

    /

    30/30

    30/40

    60/60

    /

    600/600

    Fiagure 3-4

     

    Overall dimension drawing

    EJDZW-33R drawing.jpg

    Wiring diagram

    EJDZW-33R wire drawing 1.png

    Type description: 

    E--Company name:Enboli

    J--Voltage transformer

    D--Single-phase

    Z-Casting insulation

    X--Residual,voltage,winding

    W--outdoor type

    33R--Rated voltage(kV)

     

    Technical data

    Rated

     voltage

     ration(V)

    Accuracy class and

     rated secondary output(VA)

    Max.output

    (VA)

    Rated 

    insulation

    Level(kV)

    Wiring

    diagram

    0.2

    0.5

    1grade

    3grade

    0.2/0.2

    0.5/0.5

    6P

    0.2/0.5

    parameter1.png

    20

    30

    50

    100

    /

    /

    100

    500

    36/70/170

    Fiagure 1

    parameter2.png

    /

    /

    /

    /

    20/20

    20/30

    30/30

    100

    300/300

    Fiagure 2

     

    Overall dimension drawing

     JDZXW-33R drawing.png

    Wiring diagram

     JDZXW-33R drawing 2.png


    FAQ:

    What is outdoor voltage transformer?

    The VOG outdoor voltage transformer is designed for metering line-to-ground voltage.

     Reduce weight with high performances. Resistant to outdoor conditions.

     Hydrophobic material offers superior outdoor performance and minimizes the potential for flashover.


    What is the difference between CT and VT transformers?

    CT is used as the abbreviated name to represent a current transformer. 

    PT (or sometimes VT) is used to denote a potential transformer. 

    CT reduces the large current to a safer and measurable level. PT reduces a high voltage to a safer and measurable level.


  • Website information update...
  • Power transformer Substation series Switchgear series High voltage component Electric meter New energy battery Cable jacket Wire and cable Diesel generator

LEAVE A MESSAGE

LEAVE A MESSAGE
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.