High voltage SF6 circuit breaker

High voltage SF6 circuit breaker,
(High Voltage AC SF6 Circuit Breaker)
Item No.: LW36A-126/145,
Suitable for elevation under 2500meters,50Hz、126kV.
Standards:IEC62271-100,GB1984,GB/T11022
  • Product Description
  • Profile:

    LW36A-126/145 high voltage current SF6 breaker is suitable for the areas which current is 50HZ126kV,

    and the elevation is under 2500meters,used for turning on/off the electricity system, cutting down the under-load current 

    and the short-circuit fault circuit, controlling protecting the power equipment and link circuit.

     

    Breakers uses the SF6 gas( the Alpine region use the gas mixture of SF6 and CF4) as the isolate and arc extinguishing medium,

    adopt the theory of automatic arc extinguishing,and match the spring operate instruction, 

    has the advantages of powerful turn on/off ability and lower frequency, higher reliability...etc.

     

    These products have passed the completely test of government high voltage electrical quality monitor center--

    Xian high voltage electrical research institution.

     

    The standards of high voltage SF6 circuit breaker:

    IEC62271-100  high voltage current breaker

    GB1984       high voltage current breaker

    GB/T11022    The shared technology requirements of high voltage switch equipment and control equipment standard

     

    Advantages of  high voltage SF6 circuit breaker:

    Can be used for the the current system of three phase natural grounded or ungrounded.

    Suitable for the alpine region which above is 2500m.

    Can work under the lower temperature which is -45

     

    Operating environment:

    Use normal environment conditions in accordance with the standard GB/T11022 

    《The shard technology requirements of high voltage switch equipment and control equipment standard》.

    1. The around environment temperature: -45℃~+40℃

    2. Elevation: not exceed 2500m (126kV); not exceed 1000m(145kV)

    3. Wind speed:≯34m/s

    4. Daily temperature difference:≯25℃

    5. Sunlight strength:≯0.1w/cm

    6. Monthly average relative humidity:≯90%

    7. Earthquake acceleration:Level ≯0.2g level;Vertical ≯0.1g

    8. Ice thickness:≯10mm

    9. Pollution level: Ⅲgrades( creepage distance 25mm/kV) or Ⅳgrades( creepage distance 31mm/kV)

    10. Installation : outdoor

    Main technology parameters:

    No.

    Item

    Unit

    Parameters

    1

    Rated voltage


    126

    145

    2

    Rated power frequency withstand voltage (1min)

    Over the  groundphases

    kV

    230

    275

    Between the contacts

    265

    275

    3

    Rated lightning impulse withstand voltage

    Over the groundphases

    550

    650

    Between the contacts

    630

    650

    4

    SF6 the power frequency withstand  voltage of 0meter


    95

    105

    5

    Rated frequency

    Hz

    50

    50

    6

    Rated current

    A

    3150

    3150

    7

    The first coefficient of open pole


    1.5

    1.5

    8

    Rated short-circuit on/off current

    kA

    40

    40

    9

    Rated short-circuit close/open current

    100

    100

    10

    Rated shore-time withstand current

    40

    40

    11

    Rated peak withstand current

    100

    100

    12

    Rated short-circuit continues time


    4

    4

     