Features of products:
1.Parameter:
(1).Elevation:no more than 2000m( products need to be designed separately if over 2000m)
(2).Environment temperature:Max.+50/Min.-40℃ ,the average daily temperature does not exceed 30℃
(3).The maximum average monthly relative humidity: 90%.
(4).The minimum average cloud speed of 10min: 35m/s.
(5).The maximum radial thickness of ice: 10mm
(6).Pollution grade: Ⅲ、Ⅳ grade.
2. Maximum equipment voltage: 40.5/72.5/126/252kV
3. Rated frequency: 50Hz
4. Rated primary current: 300~4000A
5. Rated secondary current: 1A or 5A
6. Quadratic Combination:0.2、0.2S、0.5、0.5S、5P、TPY、TPS grades combined as casual
7. Rated output:0.2 grade,0.2Sgrade,0.5grade,0.5Sgrade,5Pgrade:20-60VA TPY grade:10-20Ω.
8. Accurate limiting coefficient:20~40.
9. Instrument security factor: ≤5.
10. TPY grade accurate limiting condition:
A、primary time constant TP=100ms or 60ms
B、Shortage current Direct Current component 100% (means:full migration)
C、Prescribed cycle of work:C-0.1s-0-0.5S( or 0.4S)-C-0.1S-0(make sure the average accurate time is 0.4S)
D、Symmetry shortage current times:10、15、20
11. Rated isolated level: 35KV current transformer: 40.5/95/185kV
66kV current transformer: 72.5/140/325kV
110kV current transformer:126/200/480kV
220kV current transformer: 252/395/950kV
12、Short-time terminal current(short time withstand current): 50-63kA、3S
13、Rated dynamic stable current: 125-160kA(Peak Value)
14、Zero gauge pressure withstand pressure level:1.3times of the equipment Maximum working voltage
15.Partial discharge level: 1.2times of the equipment maximum working voltage ≤5
16、Yearly gas leakage rate:≤0.5%
17、SF6 gas moisture content:≤150X10-6(V/V)
18、Radio interference level: radio interference voltage ≤500μV under 1.1 times of the equipment maximum working voltage.
19、External insulation creep-age distance:25mm/kV or 31mm/kV
20、Primary terminal static load:2000N~6000N
21、Maximum amount weight of products:
35kV current transformer: 450kg( the weight of SF6: 4kg)
66kV current transformer: 500kg( the weight of SF6: 5kg)
110kV current transformer: 600kg(the weight of SF6:7kg)
220kV current transformer:1400kg( the weight of SF6:23kg)
Product type | Dimension | ||||
A | B | C | D | E | |
LVQB-35 | 1335 | 1630 | 1150 | 340 | 18 |
LVQB-66 | 1695 | 2040 | 1200 | 400 | 18 |
LVQB-110 | 2180 | 2460 | 1290 | 475 | 18 |
LVQB-220 | 3270 | 3655 | 1460 | 610 | 24 |
Technology parameter:
No. | Name |
1 | Explosion-proof equipment |
2 | 3ways shell |
3 | primary connection terminal |
4 | External insulation bushing |
5 | secondary connection terminal |
6 | Charge and release valve |
7 | Density relay |
8 | Base |
9 | Series conductor bar |
Appearance and installation diagram: