110KV SF6 current transformer

110KV SF6 high voltage current transformer
Maximum equipment voltage: 40.5/72.5/126/252kV
SF6 gas moisture content:≤150X10-6(V/V)
Item No.: LVQB(T)-36/66/110/220
  • Product Description
  • Features of products:

    1.Parameter:

    (1).Elevation:no more than 2000m( products need to be designed separately if over 2000m)

    (2).Environment temperature:Max.+50/Min.-40,the average daily temperature does not exceed 30

    (3).The maximum average monthly relative humidity: 90%.

    (4).The minimum average cloud speed of 10min: 35m/s.

    (5).The maximum radial thickness of ice: 10mm

    (6).Pollution grade: Ⅲ、Ⅳ grade.

    2. Maximum equipment voltage: 40.5/72.5/126/252kV

    3. Rated frequency: 50Hz

    4. Rated primary current: 300~4000A

    5. Rated secondary current: 1A or 5A

    6.  Quadratic Combination:0.2、0.2S、0.5、0.5S、5P、TPY、TPS grades combined as casual

    7. Rated output:0.2 grade,0.2Sgrade,0.5grade,0.5Sgrade,5Pgrade:20-60VA TPY grade:10-20Ω.

    8. Accurate limiting coefficient:20~40.

    9. Instrument security factor: ≤5.

    10. TPY grade accurate limiting condition:

    A、primary time constant TP=100ms or 60ms

    B、Shortage current Direct Current component 100% (means:full migration)

    C、Prescribed cycle of work:C-0.1s-0-0.5S( or 0.4S)-C-0.1S-0(make sure the average accurate time is 0.4S)

    D、Symmetry shortage current times:10、15、20

    11. Rated isolated level: 35KV current transformer: 40.5/95/185kV

    66kV current transformer: 72.5/140/325kV

    110kV current transformer:126/200/480kV

    220kV current transformer: 252/395/950kV

    12、Short-time terminal current(short time withstand current): 50-63kA、3S

    13、Rated dynamic stable current: 125-160kA(Peak Value)

    14、Zero gauge pressure withstand pressure level:1.3times of the equipment Maximum  working voltage

    15.Partial discharge level: 1.2times of the equipment maximum working voltage ≤5

    16、Yearly gas leakage rate:≤0.5%

    17、SF6 gas moisture content:≤150X10-6(V/V)

    18、Radio interference level: radio interference voltage ≤500μV under 1.1 times of the equipment maximum working voltage.

    19、External insulation creep-age distance:25mm/kV or 31mm/kV

    20、Primary terminal static load:2000N~6000N

    21、Maximum amount weight of products:

     35kV current transformer: 450kg( the weight of SF6: 4kg)

     66kV current transformer: 500kg( the weight of SF6: 5kg)

     110kV current transformer: 600kg(the weight of SF6:7kg)

    220kV current transformer:1400kg( the weight of SF6:23kg)

     

    Product type

    Dimension

    A

    B

    C

    D

    E

    LVQB-35

    1335

    1630

    1150

    340

    18

    LVQB-66

    1695

    2040

    1200

    400

    18

    LVQB-110

    2180

    2460

    1290

    475

    18

    LVQB-220

    3270

    3655

    1460

    610

    24

     

     

    Technology parameter:

    Connection terminal size.jpg 

    No.

    Name

    1

    Explosion-proof equipment

    2

    3ways shell

    3

    primary connection terminal

    4

    External insulation bushing

    5

    secondary connection terminal

    6

    Charge and release valve

    7

    Density relay

    8

    Base

    9

    Series conductor bar

     

     

    Appearance and installation diagram:

    Connection terminal size -appearance.jpg 