+86 139 6879 9444 / +86 151 5777 5432
  • 160kW integrated double gun DC charger
  • 160kW integrated double gun DC charger

160kW integrated double gun DC charger

Overall output power: 160kW
Single gun full power 160KW,double gun average 80KW.
Item No.: 200406031602
  • Product Description
  • FAQ:

    1.What is 3 phase 5 wire system?

    AC power is usually distributed in a facility in a 3-phase system consisting of 5 wires. 

    Three of the wires are current carriers and are called phases. 

    These 3 phases are 120 degrees out of phase from each other. The fourth wire is the neutral wire.

     

    2. The advantage of DC charger(dc intelligent charging pile).

    Unlike AC chargers, a DC charger has the converter inside the charger itself. 

    That means it can feed power directly to the car's battery and doesn't need the onboard charger to convert it. 

    DC chargers are bigger, faster, and an exciting breakthrough when it comes to EVs.

     

    Basic parameter

    Product name

    160kW integrated double gun DC charger (equalizing charge)--dc intelligent charging pile

    AC input

    AC380V±15%

    DC output voltage

    200-750VDC

    Constant power voltage range

    300-750VDC

    Overall output power

    160kW

    Maximum output current of the whole machine

    500A

    Single circuit maximum current

    250A

    Number of outputs 

    2 gun

    Power distribution mode

    Single gun full power160kWDouble gun average80kW

    Degree of protection

    IP54

    Overall dimensions

    Overall size: 750*600*1770

     

    Performance parameter

    Category

    Name

    Parameter

    AC input

    Input system

    Three phase five wireA+B+C+N+PE)

    Input voltage range

    AC380V±15%

    Input frequency

    50±1Hz

    DC output

    Voltage stabilization accuracy

    ≤±0.5%

    Current stabilization accuracy

    ≤±1%

    Output Voltage Ripple

    Peak coefficient 0.5%, effective value 0.5%

    Performance&function

    Power factor

    0.99

    Efficiency

    95%

    Standby power consumption

    0.03% of rated output power

    Current sharing unbalance

    ≤±3%

    Protection

    Input overvoltage and undervoltage protection,

    Environment condition

    Operating ambient temperature

    -20~+50, derating is required above 50


    Relative humidity

    5%~95% (no condensation)


    Altitude

    2000m, derating is required above 2000m

     

     

  • Website information update...
  • Power transformer Substation series Switchgear series High voltage component Electric meter New energy battery Cable jacket Wire and cable Diesel generator

LEAVE A MESSAGE

LEAVE A MESSAGE
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.