Product name:
S11 series 20kV distribution transformer
Brief instruction:
The Abbreviation "Change" Refers To A Static Electrical Appliance In A Power Distribution System That Converts
AC Voltage And Current According To The Law Of Electromagnetic Induction To Transmit AC Power.
In Some Areas, Power Transformers With A Voltage Level Below 20 KV Are Called "Distribution Transformers"
Or "Blending" For Short. The Installation Of "Matched" Places And Places Is Both A Substation.
Distribution Transformers Should Be Installed On The Column Or Open Floor Installation.
Technical parameters:
Rated Capacity (kVA) | Voltage Group | Connection Method | Impedance Voltage | Loss | No-load Current (100%) | Weight(kg) | (LXBXH)(mm) Outline dimension | Gauge Vertical/ Horizontal | ||||
High voltage | Low Voltage | No load | load | Machine weight | Oil Weight | Gross weight | ||||||
50 | 23 22 20 | 0.4 | Yyno Dyn 11 | 5.5 | 0.17 | 1.15 | 2.0 | 200 | 145 | 465 | 920*610*1000 | 450/380 |
100 | 0.23 | 1.92 | 1.8 | 330 | 135 | 635 | 920*680*1100 | 550/450 | ||||
125 | 0.27 | 2.26 | 1.7 | 395 | 185 | 745 | 960*780*1120 | 550/470 | ||||
160 | 0.29 | 2.69 | 1.6 | 505 | 205 | 885 | 1160*710*1180 | 550/520 | ||||
200 | 0.34 | 3.16 | 1.5 | 580 | 225 | 995 | 1190*730*1190 | 550/520 | ||||
250 | 0.41 | 3.76 | 1.4 | 695 | 245 | 1130 | 1280*820*1210 | 650/550 | ||||
315 | 0.49 | 4.53 | 1.4 | 745 | 260 | 1285 | 1380*910*1240 | 650/550 | ||||
400 | 0.58 | 5.47 | 1.3 | 865 | 305 | 1500 | 1430*950*1320 | 750/600 | ||||
500 | 0.69 | 6.58 | 1.2 | 985 | 335 | 1720 | 1520*1020*1360 | 850/660 | ||||
630 | 0.83 | 7.87 | 1.1 | 1165 | 385 | 2010 | 1680*1150*1380 | 850/660 | ||||
800 | 0.98 | 9.41 | 1.0 | 1335 | 415 | 2315 | 1810*1280*1430 | 850/660 | ||||
1000 | 1.15 | 11.54 | 1.0 | 1655 | 515 | 2985 | 1840*1290*1540 | 850/660 | ||||
1250 | 1.4 | 13.94 | 0.9 | 1890 | 630 | 3460 | 1850*1300*1730 | 850/660 | ||||
1600 | 1.7 | 16.67 | 0.8 | 2220 | 710 | 4015 | 1920*1350*1790 | 850/700 | ||||
2000 | 2.18 | 20.43 | 0.8 | 2530 | 730 | 4425 | 2020*1770*2040 | 820/820 | ||||
2500 | 2.56 | 21.85 | 0.8 | 3165 | 795 | 5260 | 2080*1800*2130 | 1070/1070 |
FAQ:
1. The usage of distribution transformers?
Distribution transformers are generally used in electrical power distribution and transmission systems.
This class of transformer has the highest power, or volt-ampere ratings, and the highest continuous voltage rating.
The power rating is normally determined by the type of cooling methods the transformer may use.
2.What are the 5 applications of transformer?
Transformers are used in a variety of applications, including
power generation, transmission and distribution, lighting, audio systems, and electronic equipment.
Power generation:
Transformers are used in power plants to increase the voltage of the electricity generated by the plant before it is sent to the grid.