GCS low voltage panel mill

GCS type low-voltage extraction switchgear (low voltage switchgear), suitable for power plant, petroleum, chemical, metallurgy, textile, high-rise building and other industries of power distribution system.
The Device Accords With Standards IEC439-1 And GB7251.1
  • Product Description
  • gCS brief instruction:

    GCS Type Low-Voltage Extraction Switchgear, Suitable For Power Plant, Petroleum, Chemical, Metallurgy, Textile, 

    High-Rise Building And Other Industries Of Power Distribution System. 

    In Large Power Plants, Petrochemical
    The System And Other Places With High Degree
    Of Automation, Requiring The Interface With The Computer,

     As The Three-Phase AC Frequency Of 50(60)Hz, Rated Working Voltage Of 400V, 660V, Rated Current

    A Low-Voltage Power Distribution Set For Distribution, 

    Motor Centralized Control And Reactive Power Compensation In Power And Supply Systems Of 5000A Or Less.

    the device accords with standards IEC439-1 and gB7251.1


    GCS the main technical parameters:

    Rated voltage 

    of main circuit(V)


    AC 380(400) (660)

    Rated short time

    withstand current of 

    bus bar(kA/1s)50、 80

    Rated voltage

     of auxiliary circuit(V)

    Rated peak withstand

    current of bus bar

    (kA/O.1s) 105、176

    AC 220 380(400)

    Line frequency

    test voltage(V/1min) 

    DC 110 220Main circuit 2500

    Rated frequency(Hz)

    50(60)

    Auxiliary circuit 1760

    Rated insulation voltage(V)

    660(1000)

    Bus bar
    Rated current(A)

    Three-phas

    four-wire system

    A.B.C.N

    Horizontal bus bar ≤4000

    Three-phase

    ve-wire system

    A.B.C.PE.N

    (MCC) Vertical bus bar 1000

    Protection grade

    IP30、IP40



    GCS Main feature

    1.Main framework adopts 8MF bar steel.Both sides of bar steel isinstalled with 

    9.2mm mounting hole with modulus 20mm and100mm. Inner installation is flexible and easy.


    2.Two types of assembly form design for main framework,

    full assembly structure and partial (side frame and cross rail) welding structure for user selection.


    3.Each function compartment of device is separated mutually

    The compartments are divided into function unit compartment, bus

    bar compartment and cable compartment.

    Each one hasrelative independent function


    4. Horizontal bus bar adopts cabinet back level placed array pattern 

    for enhancing the capacity of resisting electrodynamic force for bus bar. 

    It is the basic measure for obtaininghighshort circuitstrength capacity for main circuit.

    5.Cable compartment design makes cable outlet and inlet up and down convenient.


    GCS Use environmental conditions

    1.Ambient air temperature:-5℃~+40C and the average temperature should not exceed +35°C in 24h.


    2. Relative humidity should not exceed 50% at max temperature.

    Higher relative humidity is allowed at lower temperature. Ex.90% at+20℃.

    But in view of the temperature change,it is possible that moderate dews will produce casually.


    3. Altitude above sea level should not exceed 2000M.


    4. Installation gradient not exceed 5°


    5. Indoor without dust, corrosive gas and rain water attack.